The Orings can be placed also on cylindrical parts, drop the tool on an circular edge or face and the Orings inherits the shaft dimensions.
The family of Orings can be selected using the two tabs.
You can change the type of Orings clicking of the option buttons placed under the tabs.
The lower section of the dialog contains the items useful to set the information related to the component.
The section is divided in two parts: BOM Information and Custom Information.
For a detailed explanation see BOM information
The status bar reports the description of the selected standard rule. If you click on description Library Data Manager starts to modify the description and the rules to create the bill of materials. Close to it, on the right, there is a button that enable you to edit the geometric data file, launching the Library Data Manager - Geometry…
Every component defined in the User Interface has behind him some data files which contain properties and parameters related to the component itself. These files are placed in the folder of the standard rule. The main files associated to the family of components are the followings: ORing.ini and OringN.UNI
Every numbered section is related to an icon of the component in the User Interface, and every record contains these fields:
For example, this is the structure of a ORing.ini file
# Data file Rule Description Material File
[1]
ShaftDynAS.UNI | AS/BS | O-Rings dynamic seal for shaft | orings.dat
ShaftDynSMS.UNI | SMS | O-Rings dynamic seal for shaft | orings.dat
ShaftDynM.UNI | Metrico | O-Rings dynamic seal for shaft | orings.dat
[2]
ShaftStaAS.UNI | AS/BS | O-Rings static seal for shaft | orings.dat
ShaftStaSMS.UNI | SMS | O-Rings static seal for shaft | orings.dat
ShaftStaM.UNI | Metrico | O-Rings static seal for shaft | orings.dat
[3]
HoleDynAS.UNI | AS/BS | O-Rings dynamic seal for hole | orings.dat
HoleDynSMS.UNI | SMS | O-Rings dynamic seal for hole | orings.dat
HoleDynM.UNI | Metrico | O-Rings dynamic seal for hole | orings.dat
[4]
HoleStaAS.UNI | AS/BS | O-Rings static seal for hole | orings.dat
...
...
Under each section it is possible to place several records; every record refers to a particular rule.
The material data file contains all the materials available for the component. All the material files are stored in the folder Norme.
The OringN.UNI files, contain the fields of the standard values related to oring normative; the structure of the files are self-explaining.
## =================================================================================
## * IronPROLibrary Data Manager - *** Fronema Srl *** - www.ironcad.it
## =================================================================================
## Saved On: 30/06/2019 18:11:00
## ---------------------------------------------------------------------------------
## CODE | A | B | C | d1 | d2 (Toro) | AFT |PartNumber(Optional)|
## ---------------------------------------------------------------------------------
OR2007 | 2.0 | 5.2 | 2.5 | 1.78 | 1.78 | 1.0 |
OR2010 | 2.5 | 5.7 | 2.5 | 2.57 | 1.78 | 1.0 |
OR2012 | 3.0 | 6.2 | 2.5 | 2.90 | 1.78 | 1.0 |
OR2015 | 4.0 | 7.2 | 2.5 | 3.69 | 1.78 | 1.0 |
OR2018 | 4.5 | 7.7 | 2.5 | 4.48 | 1.78 | 1.0 |
OR2021 | 5.0 | 8.2 | 2.5 | 5.28 | 1.78 | 1.0 |
OR2025 | 6.0 | 9.2 | 2.5 | 6.07 | 1.78 | 1.0 |
OR106 | 7.0 | 10.2 | 2.5 | 6.75 | 1.78 | 1.0 |
OR2031 | 8.0 | 11.2 | 2.5 | 7.66 | 1.78 | 1.0 |
OR108 | 9.0 | 12.2 | 2.5 | 8.73 | 1.78 | 1.0 |
OR109 | 9.0 | 13.8 | 3.5 | 9.13 | 2.62 | 1.0 |
...
...